Plumbing for a Second Floor Bathroom : Plumbing Repairs

Plumbing for a Second Floor Bathroom : Plumbing Repairs

Subscribe Now:
http://www.youtube.com/subscription_center?add_user=ehowatHomeChannel

Watch More:
http://www.youtube.com/ehowatHomeChannel

When plumbing for a second floor bathroom, there are a few important considerations that you’re definitely going to need to make. Learn about plumbing for a second floor bathroom with help from a contractor with over ten years of experience in this free video clip.

Expert: Joshua Clement
Filmmaker: Joshua Clement

Series Description: You’d be surprised by just how many of the plumbing problems in your home you can fix inexpensively on your own. Get tips on various types of plumbing repairs with help from a contractor with over ten years of experience in this free video series.

87,198
Like
Save


Comments

Michael Manley says:

a 3 inch hole can be cut in a 11 7/8 engineered joist as long as the Centre of the hole does not exceed 1 foot 3 inches from the edge of the bearing structure. This looks like they went past that.

Jorge Montalvo says:

CAN RUN THE PIPES THROUGH THE JOIST ?

Thomas Rains jr says:

1) You would fail inspection. You cannot have a Sanitary Tee on it's side. Ever.

2) Run the water to test for leaks? Are you serious? Um, you have to have an inspection on that rough in! This means the system has to be air tested at 5lbs, for at least 15 minutes.

Running the water does not count. replace that San T with a Wye. A San T used for drain and waste must be positioned to receive horizontal flow and direct vertical.